Product Name: |
District heating BUSCH water source heat pump chiller
|
Supply Ability: |
10000 sets |
Related proudcts |
chiller, industrial chiller, air chiller, |
Specifications |
Cooling capacity:90 kW |
Price Term: |
FOB |
Port of loading: |
Shanghai sea port |
Minimum Order |
1 set |
Unit Price: |
USD 30500 |
|
Screw air-cooled chiller(or heat pump) Screw air-cooled chiller(heater) is the unit of which applicable cooling(heating) medium is air or water in summer(winter), and its secondary refrigerant is water. When connected with fan coil units, air conditioning box, air processor together, it can be used as half of concentration and centralized the central air conditioning system; Single cold- screw air-cooled chillers are widely used in various fields of refrigeration industry.
1.Co***ring with water chiller Co***red with water chiller, Screw air-cooled chiller can get rid of huge cooling water system and a special air conditioning room. It also can be set up on the roof and outside. Installation and maintenance are very simple and convenient.
2.Precise stable water temperature As used for industrial cooling, Low temperature water that produced by air-cooled chiller could send directly to the equipment and containers, which need to keep freezing. In order to control precise stable water temperature, the water comes out of the chiller send to the Buffer pool firstly,then entrance the equipment or containers which need cooling.
3.Achieve annual refrigerate operation In the industrial cooling use aspect, screw air-cooled chiller can be used in above temperature -10℃ and achieve annual refrigerate operation in order to meet the needs of cooling industrial in the winter refrigeration, and this can be used in different kinds of low temperature cooling. After adding appropriate antifreeze in the frozen water side, it can achieve the range of 0~-15℃ in order to adapt to the different industrial cooling requirements. Usually we use Ethylene glycol ,calcium chloride, and sodium chloride as antifreeze solvent. In the application, customers are suggested set different antifreeze solution`s concentrations according to the water temperature.
4.Y-Star triangle depressurization start mode Screw air-ccoled(or heat pump)chillers use Y-Star triangle depressurization start mode. The starting electric current is onl |